Quick Menu 문의요청 프로모션 교육정보 블로그 키사이트제품

| Solution 제품

home 제품 소개 Solution 제품

Software Packages

| COMPUTER BUS STANDARDS

Bitifeye main image

| PCI EXPRESS

N5990A-010 Test Sequencer
N5990A-005 Integrated BER Counter Interface Support
N5990A-008 Remote Power Management Support
N5990A-101 PCI Express Receiver Tests
N5990A-201 Interface to PCI Express Tx Test Software
N5990A-301 PCI Express Link Training Suite
N5990A-501 PCI Express Link Equalization Tests
N5990A-011 Upgrade to current PCIe CTS Standard and Test Instrument Support
BIT-2001-0002-0 ValiFrame Option 002 – Switch System and DSGA Platform Support
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| SATA

N5990A-010 Test Sequencer
N5990A-005 Integrated BER Counter Interface Support
N5990A-008 Remote Power Management Support
N5990A-103 SATA RSG Tests
N5990A-203 Interface to SATA Tx Test Software
N5990A-303 SATA Link Training Suite
N5990A-013 Upgrade to current SATA U.T.D.-Standard and Test Instrument Support
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| USB

N5990A-010 Test Sequencer
N5990A-005 Integrated BER Counter Interface Support
N5990A-008 Remote Power Management Support
N5990A-102 USB Receiver Tests
N5990A-202 Interface USB Tx Text Software
N5990A-302 USB Link Training Suite
N5990A-012 Upgrade to current USB CTS and Test Instrument Support
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| THUNDERBOLT

N5990A-010 Test Sequencer
N5990A-005 Integrated BER Counter Interface Support
N5990A-104 Thunderbolt Receiver Tests
N5990A-020 Upgrade to current Thunderbolt Test Specification Standard and Test Instrument Support
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| MOBILE DEVICE STANDARDS

Bitifeye main image

| MIPI C-PHY

N5990A-010 Test Sequencer
M8085A-CNA MIPI C-PHY Calibration, Conformance and Characterization Procedures for M819xA AWG, Network/Floating, Perpetual License
M8085A-CTA MIPI C-PHY Calibration, Conformance and Characterization Procedures for M819xA AWG, Transportable, Perpetual License
M8085A-CN1 MIPI C-PHY Editor for M819xA AWG, Network/Floating, Perpetual License
M8085A-CT1 MIPI C-PHY Editor for M819xA AWG, Transportable, Perpetual License
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| MIPI D-PHY

N5990A-010 Test Sequencer
N5990A-005 Integrated BER Counter Interface Support
M8085A-DNA MIPI D-PHY Calibration, Conformance and Characterization Procedures for M819xA AWG, Network/Floating, Perpetual License
M8085A-DTA MIPI D-PHY Calibration, Conformance and Characterization Procedures for M819xA AWG, Transportable, Perpetual License
N5990A-260 Interface to MIPI D-PHY Tx Test Software
M8085A-DT1 MIPI D-PHY Editor for M819xA AWG, Transportable, Perpetual License
M8085A-DN1 MIPI D-PHY Editor for M819xA AWG, Network License
BIT-2060-0000-0 MIPI D-PHY Frame Generator for M819xA AWG
BIT-2001-0002-0 ValiFrame Option 002–Switch System and DSGA Platform Support
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| MIPI M-PHY

N5990A-010 Test Sequencer
N5990A-165 MIPI M-PHY Receiver Tests
N5990A-167 UFS/UniPro Rx Physical Conformance Test Matrix
N5990A-265 Interface to MIPI M-PHY Tx Test Software
N5990A-366 MIPI M-PHY Frame Generator
N5990A-367 MIPI M-PHY/Unipro Error Counter and Test Script Wizard
N5990A-368 MIPI M-PHY Protocol-specific macros for LLI, SSIC and DigRF v4
N5990A-018 Upgrade to MIPI M-PHY Compliance Test Specification Standard and and Test Instrument Support
BIT-2001-0002-0 ValiFrame Option 002–Switch System and DSGA Platform Support
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| MHL

N5990A-010 Test Sequencer
N5990A-153 MHL Receiver Tests
BIT-2071-0154-0 ValiFrame Option 154–MHL 3 Sink Transmitter Test
BIT-2070-0000-1 MHL Frame Generator
N5990A-252 Interface to MHL Source Test Software
N5990A-017 Upgrade to current MHL Compliance Test Suite standard and Test Instrument Support
BIT-2001-0002-0 ValiFrame Option 002–Switch System and DSGA Platform Support
BIT-2071-0452-0 ValiFrame Option 452–MHL Cable Test Software
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| AUDIO/VIDEO AND MEMORY BUS STANDARDS

Bitifeye main image

| HDMI

N5990A-010 Test Sequencer
N5990A-005 Integrated BER Counter Interface Support
N5990A-151 HDMI Sink Tests
N5990A-250 Interface to HDMI Source Test Software
BIT-2010-0005-0 HDMI Frame Generator
N5990A-350 HDMI EDID, CEC and Protocol, Audio, Video Tests
N5990A-351 HDMI HEAC tests
N5990A-014 Upgrade to current HDMI Compliance Test Specification Standard
BIT-2001-0002-0 ValiFrame Option 002–Switch System and DSGA Platform Support
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| DisplayPort

N5990A-010 Test Sequencer
N5990A-155 DisplayPort Receiver Tests
N5990A-156 eDP Receiver Tests Add-On
N5990A-157 DisplayPort Type-C and Alt Mode Receiver Tests Add-On
N5990A-255 Interface to DisplayPort Tx Test Software
N5990A-015 Upgrade to current DP Compliance Test Specification standard and Test Instrument Support
BIT-2001-0002-0 ValiFrame Option 002–Switch System and DSGA Platform Support
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| SD UHS-II

N5990A-010 Test Sequencer
N5990A-120 SD UHS-II Receiver Tests
N5990A-019 Upgrade to current SD UHS-II Test Specification Standard and Test Instrument Support
BIT-2081-0220-0 ValiFrame Option 220–Interface to UHS-II Tx Software
BIT-2001-0000-0 One year N5990A S/W Maintenance Extension

| CABLE AND CONNECTOR TEST STANDARDS

Bitifeye main image

| USB TYPE-C, USB 3.1 Gen2 / USB 3.0 / USB 2.0

BIT-2041-0402-1 USB CabCon Test Software for Keysight ENA-TDR
BIT-2041-9402-1 USB CabCon Test Software Bundle for Keysight ENA-TDR
BIT-2041-0032-0 Upgrade to Current CTS for Keysight ENA-TDR
BIT-2001-0002-0 Switch System and DSGA Platform Support

| HDMI 1.4 (2.0)

BIT-2011-0450-0 HDMI Cable Test Software for Keysight ENA-TDR
BIT-2011-9450-0 HDMI Cable Test Software Bundle for Keysight ENA-TDR
BIT-2001-0002-0 Switch System and DSGA Platform Support

> BASE OPTIONS

| One Year Software Maintenance Extension / BIT-2001-0000-0

ValiFrame/N5990A One Year Software Maintenance Extension Lic. Sheet On-going product enhancements. First year included in N5990A Core Product (opt. 010) and N5990A upgrade options (e.g. opt. 011) . Minor CTS updates included . Major CTS updates excluded; require N5990A upgrade options

| TEST SEQUENCER / OPTION 010

Contains GUI, Report Generation, Remote Interface and 1 yr S/W Maintenance. Is needed to run all flavors of ValiFrame Test Automation Software (Options 100 – 199). Can be added to M8085A, when a Test Sequencer function is required.

| DATA BASE AND WEB BROWSER INTERFACE / OPTION 001

Option 001, the Database and Web-Interface adds the ability to store the procedure results in a database. These results will be reloaded once you select the same DUT again. You can also review the results using the web viewer. The web viewer works from any connected PC without a need for starting ValiFrame or having a separate license on that PC. The option hereby allows you to view the test results even if the system is occupied by a colleague.

| SWITCH SYSTEM AND DSGA SUPPORT / OPTION 002

Allows to integrate BitifEye´s 2100 Switch System and 3000 DSGA into Valiframe. Is only needed for receiver / sink test set ups.

| MULTI-LANE (MORE THAN 2) SUPPORT / OPTION 003

Allows to use the increased functionality of the new generation test equipment (M8020A, M8190A and M8195A). Is also needed e.g. for some ParBERT test set ups such as for MIPI D_PHY.Use programmable switches to test multiple lanes without manual re-connections. This can significantly reduce test times and required user interaction. This option is only required once per test station, not once per standard.
Not all standards support this option, so please contact BitifEye.

| INTEGRATED BER COUNTER INTERFACE / OPTION 005

For some DUTs proprietary tools exist to control the device (e.g. set it to loopback mode) as well as for reading internal checksum error counters, burst counters, or other indicators. These indicators make it possible to determine whether the receiver was able to receive the data properly. The integration of such proprietary tools into the Test Automation Software can be achieved with the iBerReader software interface. The interface acts as a wrapper for such tools and the definition is given in C# .NET. It follows the interface defined in the different MIPI PHY CTSs (e.g. for M-PHY: Appendix H – Standardized Software Interface for Test Automation), Computer Bus CTSs, or HDMI CTS.

| REMOTE POWER MANAGEMENT SUPPORT / OPTION 008

It is required to power-cycle the DUT several times at certain moments during the receiver tests. This means that the N5990A user needs to sit in front of the controller PC and wait until he is asked by the test automation to power-cycle the DUT. Not only is this task time-consuming, it is error prone. If the user forgets to or does not power-up the DUT properly, the current test will need to be repeated. With N5990A Option 008 or Remote Power Management Support, the number of user interactions and thus the room for errors and potential delays are minimized.
With N5990A Option 008, the user only has to make sure that the DUT is properly connected to a PDU (power distribution unit) or a Keysight power supply once during the very first receiver test and let the test automation power-cycle the DUT when required.
Suppoted PDUs are Koukaam NetIO-230B, Koukaam NetIO-230C, Allnet ALL 4076, Synaccess NP (USA connectors) Keysight Power Supplies (only used with USB tests): E3631A, E363xA, E364xA,N67xx

| USER PROGRAMMING / OPTION 500

The test platform is flexible and open. This means you can integrate your own C# code or program your own test sequences with the user programming option.
You can also easily integrate software dynamic link libraries (dlls) implemented in graphical environments such as LabView or VEE.
With this feature the user can implement custom calibration and test procedures as well as instrument drivers. Custom procedures can then be run from the ValiFrame user interface and access custom instruments. It is also possible to extend and modify existing procedures. We provide an example VisualStudio solution and documentation about the relevant ValiFrame classes to get you started with this.
This option is not required to programmatically control ValiFrame from another program through the ValiFrameRemote interface. That functionality is already included in every ValiFrame base license.